Monitoring railway vehicles safely

Monitoring railway vehicles safely

Railcars, locomotives

Power supply for drive and ancillary units

Locomotives and railcars need electrical power. The power for this is produced using a diesel generator on board or fed in to the vehicle from above from an overhead line or power rail. These drives on board the locomotives or railcars are normally unearthed and therefore need to be secured by means of a special insulation monitoring device. Bender insulation monitoring devices come in an RW variant to meet the specific requirements in terms of shock, vibration and temperature-resistance. Earthed power supplies can be protected via residual current monitors and voltage relays.

REQUEST ADVICE

Block trains, carriages

Easy insulation fault location for seamless and safe operation

The carriages in passenger trains, and also refrigerated carriages for freight transport, for example, need separate power supplies which are fed from the locomotive. Using special insulation monitoring devices, Bender can detect faults very early and quickly pinpoint them using insulation fault location devices in accordance with EN 61557-9. This clearly minimises the potential risk for passengers, crew and equipment.

REQUEST ADVICE

Downloads

NameCategorySizeLanguageTimestampD-/B-Number
Power Quality/Measuring and monitoring relays Product Overviews 2.7 MB EN2022/05/2525.05.2022
Product Overview ISOMETER®/ISOSCAN® Product Overviews 5.3 MB EN2024/02/1616.02.2024
Product Overview - Residual Current Monitoring Product Overviews 6.2 MB EN2023/11/0909.11.2023
Railway Technology Market Segment Brochures 5.5 MB EN2023/11/1313.11.2023
Insulation Fault Location - Planning and Setup Technical article 112.4 KB EN2019/05/1313.05.2019
Why the IT System is Often the Best Choice for Power Supply Systems of All Types Technical article 3.0 MB EN2019/07/1111.07.2019
Predict and Protect - Signal Power Fault Detection Systems Market Segment Brochures 1.7 MB EN2019/05/1313.05.2019

Products

Insulation monitoring

ISOMETER® isoRW425
ISOMETER® isoRW425

Insulation monitoring device for railway applications up to AC/DC 440 V

ISOMETER® isoRW685W-D
ISOMETER® isoRW685W-D

Insulation monitoring device tailored to the requirements of railway rolling stock applications

Insulation fault location

ISOSCAN® EDS440
ISOSCAN® EDS440

Insulation fault locator for localisation of insulation faults in main circuits

ISOSCAN® EDS460-D
ISOSCAN® EDS460-D

- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.

Residual current monitoring

LINETRAXX® SmartDetect RCMS410

Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems

LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor

Measuring and monitoring relays

LINETRAXX® VMD258
LINETRAXX® VMD258

Undervoltage/overvoltage relay for monitoring three-phase AC systems (window discriminator function)

Insulation monitoring

ISOMETER® isoRW425
ISOMETER® isoRW425

Insulation monitoring device for railway applications up to AC/DC 440 V

Details
ISOMETER® isoRW685W-D
ISOMETER® isoRW685W-D

Insulation monitoring device tailored to the requirements of railway rolling stock applications

Details

Insulation fault location

ISOSCAN® EDS440
ISOSCAN® EDS440

Insulation fault locator for localisation of insulation faults in main circuits

Details
ISOSCAN® EDS460-D
ISOSCAN® EDS460-D

- This device series is in the discontinuation phase. -
Deliverable according to availability until 01.01.2025.

Details

Residual current monitoring

LINETRAXX® SmartDetect RCMS410

Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems

Details
LINETRAXX® RCMS460-D
LINETRAXX® RCMS460-D

Multichannel AC, pulsed DC and AC/DC sensitive residual current monitor

Details

Measuring and monitoring relays

LINETRAXX® VMD258
LINETRAXX® VMD258

Undervoltage/overvoltage relay for monitoring three-phase AC systems (window discriminator function)

Details

Standards

EN 61557-8

Electrical safety in low voltage distribution systems up to 1 000 v a.c. and 1 500 v d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems.

EN 61557-9

Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems

DIN VDE 0115-1

Bahnanwendungen - Allgemeine Bau- und Schutzbestimmungen - Zusätzliche Anforderungen

DIN EN 50155

Railway applications - Electronic equipment used on rolling stock

DIN EN 50121-3-2

Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus

qhy4raey

Do you have any questions?

Please contact us! We are here to help.

TO CONTACT FORM